Compendium: OM SIP – DECT Solution Small SIP-DECT System
Set up RFPs and Basic Telephony
>OM System Manual:
Initial Setup
The RFP that operates as OMM offers two configuration methods: the OMM Web
service that you can access with a web browser and the OMP Java tool. Use the
OMM Web service for initial setup that includes the following basic steps.
1. Start a browser and navigate to the IP address of the OMM. Log in using the
“omm / omm” default credentials. Accept the displayed license text. Change
the password for the “Full access” and the “Root/SSH” accounts.
2. Navigate to the System: System settings page. Change the DECT: Regulatory
domain setting.
>OM System Manual:
Licensing
3. For the built-in license, configure the PARK code printed on the installation
medium on the System: System settings page. If you have received a license
file, import the file on the Licenses page.
>OM System Manual:
“Radio fixed parts” Menu
4. Navigate to the Radio fixed parts page. Click the Scan button. Click the Stop
button to view the list that should include the RFP running the OMM. Click on
the Configure icon and activate the DECT settings option. Accept the default
DECT cluster (“1”) by clicking OK. Repeat this step to configure all RFPs.
The following screenshot depicts the Status and Radio fixed parts pages for a
single RFP L43 WLAN with a built-in license that is also used as OMM.